Preview

Agricultural Engineering (Moscow)

Advanced search

Analysis of the load of power transformers with a higher voltage of 6‑10 kV

https://doi.org/10.26897/2687-1149-2023-6-67-75

Abstract

Power transformers 6‑10/0.4 kV feeding 0.4 kV rural electric networks operate with low load factors. This leads to significant electricity losses. Optimization of the load of 6‑10/0.4 kV power transformers will increase their energy efficiency. To assess the load and loss of electricity in power transformers with a higher voltage of 6‑10 kV of rural electric networks in the Orel district of electric networks (DEN) of the branch of PJSC Rosseti Tsentr – Orelenergo, the authors carried out an analysis of statistical data obtained from operational and technological group dispatcher logs on the load of power transformers 6‑10/0.4 kV of electric networks for 2016‑2022. As a result, it was found that 880 power transformers (74% of the total number) operate with a load factor of less than 20%. Among the 6‑10/0.4 kV power transformers with rated powers of 63, 100, 160, and 250 kVA, the load factor of less than 20% accounts for 72‑77%. It is established that in power transformers 6‑10/0.4 kV of the Orel DEN, annual losses of idle power are 1.8‑2.9 times higher than the short circuit losses. It is revealed that the share of idling losses for different nominal capacities of power transformers 6‑10/0.4 kV is 65‑74% of the total annual electricity losses. The assessment of the load of power transformers is necessary to develop a number of measures to reduce electricity losses in the 0.4 kV electrical networks of the Orel DEN: disconnecting transformers with seasonal loads; replacing underloaded and overloaded transformers with transformers of the required capacity; reequipping the fleet of 6‑10 kV power transformers with modern power transformers with energy efficiency of class X2K2 and higher.

About the Authors

A. V. Vinogradov
Federal Scientific Agroengineering Center VIM; Russian State Agrarian University – Moscow Timiryazev Agricultural Academy
Russian Federation

Aleksandr V. Vinogradov, DSc (Eng), Associate Professor

5, 1st Institutskiy Proezd Str., Moscow, 109428

49, Timiryazevskaya Str., Moscow, 127434



A. V. Vinogradova
Federal Scientific Agroengineering Center VIM
Russian Federation

Alina V. Vinogradova, CSc (Eng), Associate Professor

5, 1st Institutskiy Proezd Str., Moscow, 109428



A. V. Bukreev
Federal Scientific Agroengineering Center VIM
Russian Federation

Aleksei V. Bukreev, CSc (Eng), Senior Researcher

5, 1st Institutskiy Proezd Str., Moscow, 109428



A. A. Lansberg
Federal Scientific Agroengineering Center VIM
Russian Federation

Aleksandr A. Lansberg, Specialist, MSc student

5, 1st Institutskiy Proezd Str., Moscow, 109428



References

1. Musaev T.A., Khabibullin M.N., Shageev S.R., Fedorov O.V. Development of a methodology for accurate assessment of the actual load of transformers 6(10)-0.4 kV using data from intelligent electric energy metering systems. Electric Power. Transmission and Distribution. 2022;4:22-27. (In Rus.)

2. Fursanov M.I., Radkevich V.N. About the optimal operating modes of power transformers. Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations. 2008;2:32-38. (In Rus.)

3. Slatinova M.N. Improving energy efficiency in the distribution of electricity by rational loading of transformers. Izvestiya Tul- GU, Tekhnicheskie Nauki. 2010;1:271-276. (In Rus.)

4. Alyunov A.N., Vyatkina O.S., Akhmetova I.G., Pentiuc R.D., Sakipov K.E. Issues on optimization of operating modes of power transformers. E3S Web of Conferences. 2019;124:02015. https://doi.org/10.1051/e3sconf/201912402015

5. Bajracharya G., Koltunowicz T., Negenborn R.R., Djairam D., De Shutter B., Smith J.J. Optimization of Transformer Loading Based on Hot-Spot Temperature Using a Predictive Health Model. Proceedings of the 2010 International Conference on Condition Monitoring and Diagnostics. Tokyo. Japan. 2010. pp. 914-917.

6. Renedo C.J., Santisteban A., Ortiz F., Olmo C., Ortiz A. Evaluation of the Optimal Connection of Power Transformers in the Substations of a Hospital. Energies. 2018;11(2):419. https://doi.org/10.3390/en11020419

7. Tang Z., Li Zh., Wei J. Research on load optimization management and application of power transformers. Proceedings. SPIE12598, Eighth International Conference on Energy Materials and Electrical Engineering (ICEMEE2022). 2023;125982Z. https://doi.org/10.1117/12.2673040

8. Kaya Z., İmal N., Gökhasan O. On power transformers energy efficiency based load transfer analysis. International Journal of Energy Applications and Technologies. 2018;5(3):115-118. https://doi.org/10.31593/ijeat.442589

9. Khomenko I., Berezka S., Poliakov I. Analysis of optimum operating modes of power transformers under operating conditions. Elektrotekhnika i Elektromekhanika. 2016;6:70-73. (In Rus.) 10.20998/2074-272X.2016.6.12

10. Mironenko Yu.E. Evaluating the efficiency of loading power transformers as exemplified by the central power district of the Amur region. Nauchnye Issledovaniya. 2017;7:5-8. (In Rus.)

11. Trushnikov A.L., Radkevich V.N. Selection of rational modes of operation of power transformers according to the condition of minimum loss of active power. Vestnik Gomelskogo Gosudarstvennogo Tekhnicheskogo Universiteta im. P.O. Sukhogo, 2006;1:23-29. (In Rus.)

12. Naumov I.V., Karamov D.A., Tretyakov A.N., Yakupova M.A., Fedurinova E.S. Study of the loading of power transformers in rural power supply systems. Nadezhnost i Bezopasnost Energetiki. 2020;13(4):282-289. (In Rus.)

13. Lansberg A.A., Vinogradov A.V., Vinogradova A.V. Structure of the range of power transformers with a higher voltage of 6-10 kV as exemplified by the electric grid organization of the branch of PJSC “Rosseti Center”-“Orelenergo” serving rural electric networks. Izvestiya Vysshikh Uchebnykh Zavedeniy. Problemy Energetiki. 2021;23(5):34-45. (In Rus.)

14. Balabin A.A., Volchkov Yu.D. Increasing the reliability of the calculation of electricity losses in transformers 10(6)/0.4 kV. Mekhanizaciya i Elektrifikatsiya Selskogo Khozyaystva. 2009;4:22-23. (In Rus.)


Review

For citations:


Vinogradov A.V., Vinogradova A.V., Bukreev A.V., Lansberg A.A. Analysis of the load of power transformers with a higher voltage of 6‑10 kV. Agricultural Engineering (Moscow). 2023;25(6):67-75. (In Russ.) https://doi.org/10.26897/2687-1149-2023-6-67-75

Views: 114


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2687-1149 (Print)
ISSN 2687-1130 (Online)