<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">agroengineering</journal-id><journal-title-group><journal-title xml:lang="ru">Агроинженерия</journal-title><trans-title-group xml:lang="en"><trans-title>Agricultural Engineering (Moscow)</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2687-1149</issn><issn pub-type="epub">2687-1130</issn><publisher><publisher-name>РГАУ-МСХА</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.26897/2687-1149-2026-3-111-119</article-id><article-id custom-type="elpub" pub-id-type="custom">agroengineering-1311</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭЛЕКТРИФИКАЦИЯ И АВТОМАТИЗАЦИЯ СЕЛЬСКОГО ХОЗЯЙСТВА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>POWER SUPPLY AND AUTOMATION OF AGRICULTURAL PRODUCTION</subject></subj-group></article-categories><title-group><article-title>Причины и последствия аварийных отключений в сельских электрических сетях 0,4 кВ</article-title><trans-title-group xml:lang="en"><trans-title>Causes and consequences of emergency shutdowns in rural power grids of 0.4 kV</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-8935-7086</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Виноградова</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Vinogradova</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Виноградова Алина Васильевна, канд. техн. наук, доцент</p><p>AuthorID: 717846</p><p>109428,г. Москва, 1-й Институтский проезд, 5</p><p>302019, Орловская обл., г. Орёл, ул. Генерала Родина, 69</p></bio><bio xml:lang="en"><p>Alina V. Vinogradova, СSc (Eng), Associate Professor</p><p>Scopus ID: 5720415240; Researcher ID AAM-9111-2021</p><p>109428, , Moscow, 1st Institutskiy Proezd Str., 5</p><p>302019, Orel, Generala Rodina Str., 69</p><p> </p></bio><email xlink:type="simple">alinawin@rambler.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-8845-9718</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Виноградов</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Vinogradov</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Виноградов Александр Владимирович, д-р техн. наук, доцент, профессор</p><p>AuthorID: 690615</p><p>302019, Орловская обл., г. Орёл, ул. Генерала Родина, 69</p><p>127434, г. Москва, ул. Тимирязевская, 49</p></bio><bio xml:lang="en"><p>Aleksandr V. Vinogradov, DSc (Eng), Associate Professor</p><p>Scopus Author ID: 57201923234; Researcher ID AAW-4375-2021</p><p>302019, Orel, Generala Rodina Str., 69</p><p>127434, Moscow, Timiryazevskaya Str., 49</p></bio><email xlink:type="simple">winaleksandr@gmail.com</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7588-0458</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шогенов</surname><given-names>Ю. Х.</given-names></name><name name-style="western" xml:lang="en"><surname>Shogenov</surname><given-names>Yu. Kh.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Шогенов Юрий Хасанович, академик, д-р техн. наук, начальник сектора механизации, электрификации и автоматизации отдела сельскохозяйственных наук</p><p>Researcher ID AAR-1140-2020</p><p>119991, г. Москва, Ленинский пр-т, 14</p></bio><bio xml:lang="en"><p>Yuriy Kh. Shogenov, Full Member, DSc (Eng), Head of the Mechanization, Electrification, and Automation Sector of the Agricultural Science Department</p><p>Researcher ID AAR-1140-2020</p><p>119991, Moscow, Leninskiy Ave., 14</p></bio><email xlink:type="simple">yh1961s@yandex.ru</email><xref ref-type="aff" rid="aff-3"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Федеральный научный агроинженерный центр ВИМ; Орловский государственный аграрный университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Federal Scientific Center for VIM; Orel State Agrarian University</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Орловский государственный аграрный университет; Российский государственный аграрный университет –МСХА имени К.А. Тимирязева</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Orel State Agrarian University; Russian State Agrarian University – Moscow Timiryazev Agricultural Academy</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru"><institution>Российская академия наук</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Russian Academy of Sciences</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>30</day><month>06</month><year>2026</year></pub-date><volume>28</volume><issue>3</issue><fpage>111</fpage><lpage>119</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Виноградова А.В., Виноградов А.В., Шогенов Ю.Х., 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Виноградова А.В., Виноградов А.В., Шогенов Ю.Х.</copyright-holder><copyright-holder xml:lang="en">Vinogradova A.V., Vinogradov A.V., Shogenov Y.K.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://agroengineering.timacad.ru/jour/article/view/1311">https://agroengineering.timacad.ru/jour/article/view/1311</self-uri><abstract><p>Причины аварийных отключений в сельских электрических сетях и их последствия учитываются при прогнозировании вероятных ущербов от отключений и подборе мероприятий по повышению надежности электроснабжения сельских потребителей. Исследования проведены с целью выявления численных показателей количества и последствий аварийных отключений в сельских электрических сетях 0,4 кВ. На основе анализа статистических данных о количестве аварийных отключений и причинах их возникновения в электрических сетях 0,4 кВ Орловской области рассчитали время восстановления и время восстановления электроснабжения, отключенную мощность и количество обесточенных точек подключения в электрических сетях 0,4 кВ. Наиболее частыми причинами отключений отмечены повреждения в сетях потребителей (53%), перегорание предохранителей, схлестывание проводов (6…7%). Невыявленные причины составляют 9…11%. Значимость причин по количеству отключений, времени перерывов в электроснабжении и восстановлению, отключенной мощности может отличаться. Отключенная мощность и количество обесточенных точек напрямую зависят от количества отключений. На основе рассчитанных количественных данных рекомендуем реализовать мероприятия по повышению надежности электроснабжения сельских электрических сетей 0,4 кВ: совершенствовать конфигурацию электрических сетей, провести секционирование линий электропередачи, оснастить сети средствами мониторинга параметров режимов работы, заменить голые провода изолированными. Проведенные исследования решают проблему выявления количества и последствий аварийных отключений в сельских электрических сетях 0,4 кВ при анализе эффективности функционирования систем электроснабжения сельских потребителей.</p></abstract><trans-abstract xml:lang="en"><p>The causes of emergency outages in rural power grids and their consequences must be considered when predicting probable damage from outages and selecting measures to improve the reliability of power supply to rural consumers. The study aimed to identify numerical indicators of both the frequency and the consequences of emergency outages in 0.4 kV rural power grids. Based on the analysis of statistical data on the number of emergency outages and their causes in 0.4 kV power grids of the Orel region, the authors calculated the following parameters: restoration time, power supply restoration time, interrupted power, and the number of de-energized connection points. The most frequent causes of outages were identified as damage in consumer networks (53%), blown fuses and unidentified causes (9-11% each), and wire clashing (6-7%). However, the significance of each cause varies depending on whether one considers the number of outages, the duration of power supply interruptions, restoration time, or interrupted power. Interrupted power and the number of de-energized points are directly related to the number of outages. Based on the calculated quantitative data, the following measures are recommended to improve the reliability of power supply to 0.4 kV rural power grids: improving the configuration of power grids; sectionalizing power lines; equipping power grids with means for monitoring operating mode parameters; replacing bare wires with insulated ones. This study addresses the problem of identifying the number and consequences of emergency outages in 0.4 kV rural power grids as part of analyzing the operational efficiency of power supply systems for rural consumers.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>сельские электрические сети</kwd><kwd>электроснабжение</kwd><kwd>отключения</kwd><kwd>причины аварийных отключений</kwd><kwd>последствия аварийных отключений</kwd><kwd>отключенная мощность</kwd><kwd>количество обесточенных точек</kwd></kwd-group><kwd-group xml:lang="en"><kwd>rural power grids</kwd><kwd>power supply</kwd><kwd>outages</kwd><kwd>causes of emergency outages</kwd><kwd>consequences of emergency outages</kwd><kwd>interrupted power</kwd><kwd>number of de-energized points</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Сбитнев Е.А., Жужин М.С. Анализ аварийности сельских электрических сетей 0,38 кВ нижегородской энергосистемы // Вестник НГИЭИ. 2020. № 11 (114). С. 36-47. EDN: KEJHDX</mixed-citation><mixed-citation xml:lang="en">Sbitnev E.A., Zhuzhin M.S. Accident rate analysis of rural electric networks 0.38 kV of the Nizhny Novgorod power system. Vestnik NGIEI. 2020;11:36-47. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Васильева Т.Н., Лопатин Е.И. Анализ причин отказов электрического оборудования распределительных сетей 0,38…10 кВ // Вестник Рязанского государственного агротехнологического университета им. П.А. Костычева. 2011. № 3 (11). С. 64-66. EDN: OFSKQV</mixed-citation><mixed-citation xml:lang="en">Vasilyeva T.N., Lopatin E.I. The analysis of causes of failures of the electric equipment of distributive networks 0,38 … 10 kV. Bulletin of the Ryazan State Agrotechnological University named after P.A. Kostychev. 2011;3:64-66. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Извеков Е.А., Картавцев В.В. Оценка повышения надежности электроснабжения потребителя, резервируемого с помощью системы накопления энергии // Вестник Воронежского государственного аграрного университета. 2022. Т. 15, № 2 (73). С. 53-63. EDN: EUOHQX</mixed-citation><mixed-citation xml:lang="en">Izvekov E.A., Kartavtsev V.V. Evaluation of reliability improvement of electric power supply to a consumer reserved with the help of an energy storage system. Vestnik of Voronezh State Agrarian University. 2022;15(2):53-63. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Наумов И.В. Перспективная оценка надежности функционирования электрических сетей (на примере филиала ПАО «Россети Волги»-«Саратовские распределительные сети») // Журнал Сибирского федерального университета. Серия «Техника и технологии». 2024. Т. 17, № 3. С. 360-377. EDN: MOAVXR</mixed-citation><mixed-citation xml:lang="en">Naumov I.V. A prospective assessment of the functioning electric networks reliability using the example of the PJSC Rossetti Volga – Saratov distribution networks branch. Journal of Siberian Federal University. Engineering and Technologies. 2024;17(3):360-377. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Наумов И.В., Полковская М.Н. Аналитическая оценка функционирования распределительных электрических сетей ПАО «Россети Волга»-«Оренбургэнерго» // Журнал Сибирского федерального университета. Серия «Техника и технологии». 2024. Т. 17, № 8. С. 988-1006. EDN: XTMYHD</mixed-citation><mixed-citation xml:lang="en">Naumov I.V., Polkovskaya M.N. Analytical assessment of the functioning of distribution electric networks of PJSC Rosseti Volga – Orenburgenergo. Journal of Siberian Federal University. Engineering and Technologies. 2024;17(8):988-1006. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Виноградов А.В., Сейфуллин А.Ю., Букреев А.В. Определение рациональных мест размещения мультиконтактных коммутационных систем // Сельскохозяйственные машины и технологии. 2024. Т. 18, № 3. С. 82-90. https://doi.org/10.22314/2073-7599-2024-18-3-82-90</mixed-citation><mixed-citation xml:lang="en">Vinogradov A.V., Seyfullin A.Yu., Bukreev A.V. Determining the optimal location for multi-contact switching systems. Agricultural Machinery and Technologies. 2024;18(3):82-90. (In Russ.) https://doi.org/10.22314/2073-7599-2024-18-3-82-90</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Виноградова А.В., Виноградов А.В., Букреев А.В. Удельные показатели надежности электрических сетей 0,4 кВ // Агроинженерия. 2024. Т. 26, № 6. С. 77-85. https://doi.org/10.26897/2687-1149-2024-6-77-85</mixed-citation><mixed-citation xml:lang="en">Vinogradova A.V., Vinogradov A.V., Bukreev A.V. Study of specific reliability indicators of 0.4 kV power networks. Agricultural Engineering (Moscow). 2024;26(6):77-85. (In Russ.) https://doi.org/10.26897/2687-1149-2024-6-77-85</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Breido I., Kaverin V., Ivanov V. Telemetric Monitoring Insulation Condition of High Voltage OverheadPower Lines. Proceedings of the 29th DAAAM International Symposium, 2018. Рр. 0319-0328. https://doi.org/10.2507/29th.daaam.proceedings.046</mixed-citation><mixed-citation xml:lang="en">Breido I., Kaverin V., Ivanov V. Telemetric Monitoring Insulation Condition of High Voltage Overhead Power Lines. Proceedings of the 29th DAAAM International Symposium, 2018. Рр. 0319-0328. https://doi.org/10.2507/29th.daaam.proceedings.046</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Chatterjee S., Roy B. Prediction of line contingency catastrophic failures using synchrophasor measurements. Journal of Control Automation and Electrical Systems. 2019;30(6):1107-1115. https://doi.org/10.1007/s40313-019-00501-x</mixed-citation><mixed-citation xml:lang="en">Chatterjee S., Roy B. Prediction of line contingency catastrophic failures using synchrophasor measurements. Journal of Control Automation and Electrical Systems. 2019;30(6):1107-1115. https://doi.org/10.1007/s40313-019-00501-x</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Böhm R., Rehtanz Ch., Franke J. Strategy for implementing black start and islanded operation capabilities on distribution system level. Energy Systems Research. 2018;1(1):9-20. https://doi.org/10.25729/esr.2018.01.0001</mixed-citation><mixed-citation xml:lang="en">Böhm R., Rehtanz Ch., Franke J. Strategy for implementing black start and islanded operation capabilities on distribution system level. Energy Systems Research. 2018;1(1):9-20. https://doi.org/10.25729/esr.2018.01.0001</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
